型号
|
DX-200-2.8
|
DX-200-3.3
|
DX-200-3.8
|
DX-200-4.2
|
DX-200-4.5
|
DX-200-5
|
输 入
|
电压范围
|
180~264VAC
|
输入电流
|
230VAC/2.5A
|
效率
|
≥83%
|
≥85%
|
≥87%
|
≥87%
|
≥87%
|
≥88%
|
频率范围
|
47~63HZ
|
漏 电 流
|
<3.5mA/240VAC
|
浪涌电流
|
冷启动 45A/230VAC
|
输 出
|
直流电压
|
2.8V
|
3.3V
|
3.8V
|
4.2V
|
4.5V
|
5V
|
额定电流
|
40A
|
40A
|
40A
|
40A
|
40A
|
40A
|
功 率
|
112W
|
132W
|
152W
|
168W
|
180W
|
200W
|
电压调节范围
|
±3.0%
|
±3.0%
|
±3.0%
|
±3.0%
|
±3.0%
|
±3.0%
|
纹波及噪声
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
启动上升时间
|
2000ms,50ms/ (230VAC) 负载 100%
|
保持时间
|
20ms/230VAC 负载 100%
|
线性调整率
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
负载调整率
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
电压精度
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
±2.0%
|
磁 容
电 兼
|
电磁耐受
|
设计参考:EN55024 ;EN61000-4-2,3,4,5,6,8,11
|
谐波电流
|
NA
|
EMC 指标
|
设计参考:EN55022,Class A
|
安 规
|
安全规范
|
设计参考:GB4943/UL62368
|
耐 压
|
输入—输出 I/P-O/P:1.5KVac/10mA; 输入 机壳 I/P-CASE:1.5KVac/10mA; 输出 机壳
O/P-CASE:0.5KVAC/10mA 每项测试时间为:1min
|
绝缘阻抗
|
I/P-O/P:100M ohms; I/P-Case:100M ohms; O/P-Case:100M ohms
|
保 护
|
过压保护
|
/
|
过载保护
|
110~150% rated 打嗝模式,消除过载后可自动恢复正常工作
|
过温保护
|
/
|
短路保护
|
打嗝模式, 消除短路后可自动恢复输出
|
环境要求
|
工作温度及湿度
|
-30~70℃ 20%~95%RH 不凝露 (详请参考降额曲线)
|
储存温湿度
|
-40℃~85℃; 10%~95%RH 不凝露
|
振动
|
频率范围 10 ~ 500Hz,加速度 2G,每个扫频循环 10min.,沿 X,Y, Z 轴个进行 6 个扫频循环
|
冲击
|
加速度 20G,持续时间 11mS,沿 X,Y, Z 轴各进行 3 次冲击
|
海拔高度
|
2000mtrs (2000m 以上,每升高 100m,环境温度降低 0.6℃)
|
可 靠 性
|
MTBF
|
25℃环境下:250000Hrs, MIL-217 Method
|
其他要求
|
尺寸
|
208*59*31 mm (长*宽*高)
|
包装
|
0.45Kg/只,30 只/箱, 15.5KG/箱
|
冷却方式
|
☑ 自冷 □ 风冷
|
延伸方式
|
双三防 加盖 低温启动(-40℃) 其它
|
备 注
|
*为了延长使用寿命,建议配置负载时多留30%的余量。例如:设备需要100W的功率,则选用不小于130W的电源。
*开关电源纹波测试方法: 用20MHz示波器在电源输出端子上测试,示波器探头地线长度不大于12mm,并在探 头输入并联47uF电解电容和0.1uF高频电容。
*所有电气性能测试均在 25℃环境下完成。
*本产品满载使用时须增加400*400*3mm 面积的铝板辅助散热。
*电源是设备系统元器件的一部分,所有的EMC 测试都是将样品安装在金属板上测试的,电源需结合终端设备进 行电磁兼容相关确认。
|