Model
|
DX-25-5V
|
DX-25-12V
|
DX-25-24V
|
DX-25-48V
|
Input
|
Voltage range
|
176~264VAC
|
Input current
|
230VAC/0.33A
|
Efficiency
|
≥80%
|
≥81%
|
≥82%
|
≥82%
|
Frequency range
|
47~63HZ
|
Leakage current
|
<0 .75mA/240VAC
|
Inrush current
|
50A/230VAC cold start
|
Output
|
DC voltage
|
5V
|
12V
|
24V
|
48V
|
Rated current
|
5A
|
2. 1A
|
1. 1A
|
0.55A
|
Power
|
25W
|
25.2W
|
26.4W
|
26.4W
|
Voltage adj .range
|
4.5~5.5V
|
10.8~13.2V
|
21.6~26.4V
|
44~52V
|
Ripple and noise
|
100mVp-p
|
120mVp-p
|
150mVp-p
|
200mVp-p
|
Set up,rise time
|
≤2500ms ,≤50ms/230VAC full load
|
Hold up time
|
≥20ms/230VAC full load
|
Line regulation
|
±0 .5%
|
±0 .5%
|
±0 .5%
|
±0 .5%
|
Load regulation
|
±2 .0%
|
±1 .0%
|
±1 .0%
|
±1 .0%
|
Output Voltage
Accuracy
|
±2.0%
|
±2.0%
|
±1.0%
|
±1.0%
|
EMC
|
EMS
|
compliance to :EN55035 ;EN61000-4-2,3,4,5,6,8,11
|
Harmonic current
|
compliance to :GB17625. 1;EN61000-3-2,-3 limited
|
EMC
|
compliance to :EN55032 ,Class B
|
Safety
|
Safety standard
|
compliance to : GB4943.1/UL62368.1
|
Withstand voltage
|
I/P-O/P:I/P-O/P:3KVac/5mA; I/P-CASE:I/P-CASE:I/P-CASE:1.5KVac/5mA; O/P-CASE:O/P-CASE:0.5KVDC/5mA 1min for each test
|
Isolation
|
I/P-O/P: 100M ohms; I/P-Case:100M ohms; O/P-Case:50M ohms
|
Leak current
|
I/P-FG≤0.75mA;(Input:240Vac,frequency:50Hz)
|
Protection
|
Over voltage
|
5.8~8V
|
13.5~17V
|
27~33V
|
54~64V
|
Hiccup mode
|
Over load
|
110~160% rated Hiccup mode,auto-recovery
|
Over temperature
|
/
|
Short circuit
|
Hiccup mode,auto-recovery after remove fault condition
|
Environment
|
Working
Temp&humidity
|
-25~70C 20%~95%RH
|
Storage
Temp&humidity
|
-30C~80C; 10%~95%RH no condensing
|
Vibration
|
10~500Hz,3G ,10min/1 cycle,60min.each along X,Y, Z axes six sweep cycles
|
Impact
|
5G,last 11mS ,3 impacts along X, y and Z axes
|
Altitude
|
5000mtrs (the ambient temperature derating of 0.6 C/100m for operating altitude higher than 2000m)
|
|
|
|
Others
|
SIZE
|
91.5*51*28 mm (L*W*H)
|
Packing
|
0.23Kg/pc,96pcs/ctn ,17.5KG/ctn
|
Cooling mode
|
☑ free air □ with fan
|
Extension mode
|
|
Note
|
*In order to extend the service life, it is recommended to leave 30% more allowance when loading. For example, if the equipment needs 100W power, please choose the power supply over 130W.
*Ripple&noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.
*All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25C of ambient temperature.
*The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives.All our EMC tests are carried out by mounting samples on metal plates.
|