Model
|
DX-35-5V
|
DX-35-12V
|
DX-35-15V
|
DX-35-24V
|
DX-35-36 V
|
DX-35-48V
|
Input
|
Input voltage
|
90~264VAC
|
Input current
|
230VAC/0.42A ,115VAC/0.7A
|
Efficiency
|
≥82%
|
≥84%
|
≥85%
|
≥85%
|
≥86%
|
≥86%
|
Frequency range
|
47~63HZ
|
Leakage current
|
<1mA/240VAC
|
Inrush current
|
Cold start 60A/230VAC
|
Output
|
DC voltage
|
5V
|
12V
|
15V
|
24V
|
36V
|
48V
|
Rated current
|
7A
|
3A
|
2.4A
|
1.5A
|
1A
|
0.8A
|
Rated power
|
35W
|
36W
|
36W
|
36W
|
36W
|
38.4W
|
Voltage ADJ .range
|
4.5~5.5V
|
10.8~13.2V
|
13.5~16.5V
|
21.6~26.4V
|
33~39V
|
44~52V
|
Ripple & Noise
|
100mVp-p
|
120mVp-p
|
120mVp-p
|
150mVp-p
|
200mVp-p
|
200mVp-p
|
Set up,rise
|
≤2500ms , ≤50ms/230VAC 100% load
|
hold up time
|
≥20ms/230VAC 100% load
|
Line regulation
|
±0 .5%
|
±0 .5%
|
±0 .5%
|
±0 .5%
|
±0 .5%
|
±0 .5%
|
Load regulation
|
±2 .0%
|
±1 .0%
|
±1 .0%
|
±1 .0%
|
±1 .0%
|
±1 .0%
|
Voltage accuracy
|
±2 .0%
|
±1 .0%
|
±1 .0%
|
±1 .0%
|
±1 .0%
|
±1 .0%
|
EMC
|
EMS
|
compliance to::EN55035 ;EN61000-4-2,3,4,5,6,8,11
|
Harmonic current
|
compliance to::GB17625. 1;EN61000-3-2,-3 rated
|
EMI
|
compliance to::EN55032,Class B
|
Safety
|
Safety Standard
|
compliance to::GB4943.1:2022/UL62368.1:2021
|
Withstand voltage
|
I/P-O/P:3KVac/7mA; I/P-CASE:1.5KVac/7mA; O/P-CASE:0.5KVDC/7mA 1min for each test
|
Isolation resistance
|
I/P-O/P: 100M ohms; I/P-Case:100M ohms; O/P-Case:100M ohms
|
Leakage current
|
I/P-FG≤0.75mA;(Input 240Vac ,Frequency 50Hz)
|
Protection
|
Over Voltage
|
5.75~6.5V
|
13.5~16V
|
16.8~19.5V
|
27~32V
|
40~48V
|
53~60V
|
Voltage limited
|
Over Load
|
110~160% rated Hiccup mode,auto-recovery
|
Over Temp
|
/
|
Short Current
|
Hiccup mode,auto-recovery
|
Environment
|
Working Temp&humidity
|
-30~70C 20%~95%RH non-condensing (Refer to Derating Curve)
|
Storage
Temp&humidity
|
-40C~85C; 10%~95%RH non-condensing
|
Vibration
|
10~500Hz,2G ,10min/1 cycle,60min.each along X,Y, Z axes
|
Impact
|
20G ,last 11mS ,3 impacts along X, y and Z axes
|
Altitude
|
5000mtrs ,the ambient temperature derating of 0.6 C/100m for operating altitude higher than 2000m
|
|
|
|
Others
|
Size
|
99*82*30 mm (L*W*H)
|
Packing
|
0.2Kg/PC,60PCS/CTN ,14KG/CTN
|
Cold mode
|
☑free air convection □with fan
|
|
|
Note
|
*In order to extend the service life, it is recommended to leave 30% more allowance when loading. For example, if the equipment needs 100W power, please choose the power supply over 130W .
*Ripple&noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.
*All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25C of ambient temperature。
*The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives.All our EMC tests are carried out by mounting samples on metal plates.
|