Model
|
DX-50-5V
|
DX-50-12V
|
DX-50-15V
|
DX-50-24V
|
DX-50-36V
|
DX-50-48V
|
Input
|
Input voltage
|
90~264VAC
|
Input current
|
230VAC/0.55A
|
115VAC/1.0A
|
Efficiency
|
≥83%
|
≥85%
|
≥85%
|
≥85%
|
≥86%
|
≥86%
|
Frequency range
|
47~63HZ
|
Leakage current
|
<1mA/240VAC
|
Inrush current
|
Cold start 60A/230VAC
|
Output
|
DC voltage
|
5V
|
12V
|
15V
|
24V
|
36V
|
48V
|
Rated current
|
10A
|
4.2A
|
3.4A
|
2. 1A
|
1.4A
|
1. 1A
|
Rated power
|
50W
|
50.4W
|
51W
|
50.4W
|
50.4W
|
52.8W
|
Voltage ADJ.range
|
4.5~5.5V
|
10.8~13.2V
|
13.5~16.5V
|
21.6~26.4V
|
33~39V
|
44~52V
|
Ripple & Noise
|
100mVp-p
|
120mVp-p
|
120mVp-p
|
150mVp-p
|
200mVp-p
|
200mVp-p
|
Set up,rise
|
≤2500ms ,≤50ms/230VAC load 100%
|
Hold up time
|
≥20ms/230VAC load 100%
|
Line regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load regulation
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
Voltage accuracy
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
EMI
|
EMS
|
compliance to: EN55035 ;EN61000-4-2,3,4,5,6,8,11
|
Harmonic current
|
compliance to: GB17625. 1;EN61000-3-2,-3 limited requirements
|
EMC
|
compliance to: EN55032 ,Class B
|
Safety
|
Safety Standard
|
compliance to: GB4943/UL62368
|
Withstand voltage
|
I/P-O/P:3KVac/7mA; I/P-CASE:1.5KVac/7mA; O/P-CASE:0.5KVAC/7mA Test time:1min
|
Isolation resistance
|
I/P-O/P: 100M ohms; I/P-Case:100M ohms; O/P-Case:50M ohms
|
Protections
|
Over Voltage
|
5.75~6.5V
|
13.5~16V
|
16.8~19.5V
|
27~32V
|
40~48V
|
53~60V
|
When the main voltage loop fault causes the output voltage to rise, the secondary voltage loop (over voltage protection loop) works in real time to limit the output voltage to a safe value
|
Over Load
|
110~160% rated ,Hiccup mode,auto-recovery after fault condition removed
|
Over Temp
|
/
|
Short Current
|
Auto-recovery after fault condition removed
|
Environment
|
Working
Temp&humidity
|
-30~70C 20%~95%RH non-condensing
|
Storage
Temp&humidity
|
-30C~80C; 10%~95%RH non-condensing
|
Vibration
|
10~500Hz,3G,10min/1 cycle,60min.each along X,Y, Z axes
|
Impact
|
5G,last 11mS,3 impacts along X, Y and Z axes
|
Altitude
|
5000mtrs,the ambient temperature derating of 0.6 C/100m for operating altitude higher than 2000m
|
|
|
|
Others
|
Size
|
99*82*30 (L*W*H)
|
Packing
|
0.2Kg/pcs,60 pcs/box ,14KG/box
|
Cold mode
|
☑ Free air cooling Fan
|
More options
|
PCB double side coating Terminal with cover low temp start (-40C) Other
|
Note
|
*In order to extend the service life, it is recommended to leave 30% more allowance when loading. For example, if the equipment needs 100W power, please choose the power supply over 130W.
*Ripple&noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.
*All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25C of ambient temperature。 *The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives.All our EMC tests are carried out by mounting samples on metal plates.
|