Model
|
DX-75-5V
|
DX-75-12V
|
DX-75-15V
|
DX-75-24V
|
DX-75-36V
|
DX-75-V48
|
Input
|
Voltage range
|
90~264VAC
|
Input current
|
230VAC/0.85A
|
Efficiency
|
≥83%
|
≥85%
|
≥85%
|
≥85%
|
≥86%
|
≥86%
|
Frequency range
|
47~63HZ
|
Leakage current
|
<1mA/240VAC
|
Inrush current
|
Cold start 60A/230VAC
|
Output
|
DC voltage
|
5V
|
12V
|
15V
|
24V
|
36V
|
48V
|
Rated current
|
12A
|
6A
|
5A
|
3.2A
|
2. 1A
|
1.6A
|
Power
|
60W
|
72W
|
75W
|
76.8W
|
75.6W
|
76.8W
|
Voltage adj.range
|
4.5~5.5V
|
10.8~13.2V
|
13.5~16.5V
|
21.6~26.4V
|
33~39V
|
44~52V
|
Ripple and noise
|
100mVp-p
|
120mVp-p
|
120mVp-p
|
150mVp-p
|
200mVp-p
|
200mVp-p
|
Set up,rise time
|
≤ 2500ms , ≤50ms/230VAC full load
|
Hold up time
|
≥ 20ms/230VAC full load
|
Line regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load regulation
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
Output Voltage Accuracy
|
±2.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
EMC
|
EMS
|
compliance to: EN55035 ;EN61000-4-2,3,4,5,6,8,11
|
Harmonic current
|
compliance to: GB17625. 1;EN61000-3-2,-3 limited
|
EMC
|
compliance to: EN55032 ,Class B
|
Safety
|
Safety standard
|
compliance to: GB4943.1:2022/UL62368.1:2021
|
Withstand voltage
|
I/P-O/P:3KVac/7mA;I/P-CASE:1.5KVac/7mA; O/P-CASE:0.5KVAC/7mA 1min for each test
|
Isolation
|
I/P-O/P: 50M ohms; I/P-Case:50M ohms; O/P-Case:50M ohms
|
Protection
|
resistance
Over voltage
|
5.75~6.5V
|
13.5~16V
|
16.8~19.5V
|
27~32V
|
40~48V
|
53~60V
|
Voltage output limited
|
Over load
|
110~160% rated Hiccup mode,auto-recovery after fault condition removed
|
Over temperature
|
/
|
Short circuit
|
Hiccup mode,auto-recovery after fault condition removed
|
Environment
|
Working Temp&humidity
|
-30~70℃ 20%~95%RH no condensing (refer to derating curve)
|
Storage Temp&humidity
|
-30℃~80℃; 10%~95%RH no condensing
|
Vibration
|
10~500Hz,2G ,10min/1 cycle,60min.each along X,Y, Z axes six sweep cycles
|
Impact
|
20G,last 11mS ,3 impacts along X, y and Z axes
|
Altitude
|
5000mtrs (the ambient temperature derating of 0 .6 ℃/100m for operating altitude higher than 2000m)
|
Reliability
|
MTBF
|
Under 25℃:100000Hrs, MIL-217 Method
|
Others
|
SIZE
|
99*97*30 (L*W*H)
|
Packing
|
0.25Kg/piece,60 pc/ctn ,16KG/ctn
|
Cooling mode
|
☑Free air cooling Fan
|
Extension mode
|
PCB double side conformal coating ☑ block with cover low temp start (-40℃) Other
|
Note
|
*In order to extend the service life, it is recommended to leave 30% more allowance when loading. For example, if the equipment needs 100W power, please choose the power supply over 130W.
*Ripple&noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.
*All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature.
*The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives.All our EMC tests are carried out by mounting samples on metal plates.
|