Model
|
DX-200-12V
|
DX-200-15V
|
DX-200-24V
|
DX-200-36V
|
DX-200-48V
|
Input
|
Voltage range
|
90~132VAC/176~264VAC by switch
|
Input current
|
230VAC/2. 1A 115VAC/4.2A
|
Efficiency
|
85%
|
85%
|
86.5%
|
88%
|
88%
|
Frequency range
|
47~63HZ
|
Leakage current
|
<0.75mA/240VAC
|
Inrush current
|
COLD START 60A/230VAC
|
Output
|
DC voltage
|
12V
|
15V
|
24V
|
36V
|
48V
|
Rated current
|
16.7A
|
13.3A
|
8.3A
|
5.5A
|
4. 1A
|
Power
|
200.4W
|
201W
|
199.2W
|
198W
|
196.8W
|
Voltage adj.range
|
±10.0%
|
±10.0%
|
±10.0%
|
±10.0%
|
±10.0%
|
Ripple and noise
|
≤150mVp-p
|
≤150mVp-p
|
≤250mVp-p
|
≤250mVp-p
|
≤250mVp-p
|
Set up,rise time
|
≤ 2500ms ,≤ 140ms/230VAC 100% LOADING
|
Hold up time
|
≥ 20ms/230VAC 100% LOADING
|
Line regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load regulation
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
Output Voltage
Accuracy
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
EMC
|
EMS
|
compliance to: EN55035 ;EN61000-4-2,3,4,5,6,8,11
|
Harmonic current
|
NA
|
EMC
|
compliance to: EN55032,class B
|
Safety
|
Safety standard
|
compliance to: GB4943.1:2022/UL62368.1:2021-03
|
Withstand voltage
|
I/P-O/P:3KVac/5mA;I/P-CASE:1.5KVac/5mA; O/P-CASE:0.5KVAC/5mA 1min for each test
|
Isolation resistance
|
I/P-O/P:100M ohms; I/P-Case:100M ohms; O/P-Case:50M ohms
|
Protection
|
Over voltage
|
13.5~16.5V
|
16.8~20.3V
|
27~33V
|
41~48V
|
54~64V
|
Voltage limited
|
Over load
|
110~150% rated Hiccup mode,auto-recovery after fault condition removed
|
Over temperature
|
/
|
Short circuit
|
Hiccup mode,auto-recovery after fault condition removed
|
Environment
|
Working
Temp&humidity
|
-30~70℃ 20%~95%RH no condensing (refer to derating curve)
|
Storage
Temp&humidity
|
-40℃~85℃ 10%~95%RH no condensing
|
Vibration
|
10~500Hz,2G ,10min/1 cycle,60min.each along X,Y, Z axes six sweep cycles
|
Impact
|
20G,last 11mS ,3 impacts along X, y and Z axes
|
Altitude
|
the ambient temperature derating of 0.6 ℃/100m for operating altitude higher than 2000m
|
Reliability
|
MTBF
|
Under 25℃:250000Hrs, MIL-217 Method
|
Others
|
SIZE
|
215*115*30 mm (L*W*H)
|
Packing
|
0.3Kg/piece,40pcs/ctn ,16KG/ctn
|
Cooling mode
|
☑Free air cooling □ Fan
|
Extension mode
|
□ PCB double side conformal coating ☑ block with cover □ low temp start (-40℃)
□ Other
|
Note
|
*In order to extend the service life, it is recommended to leave 30% more allowance when loading. For example, if the equipment needs 100W power, please choose the power supply over 130W.
*Ripple&noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.
*All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature.
*The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives.All our EMC tests are carried out by mounting samples on metal plates.
|