Model
|
DX-350-12V
|
DX-350-15V
|
DX-350-24V
|
DX-350-27
|
DX-350-36V
|
DX-350-48V
|
DX-350-55V
|
Input
|
Voltage range
|
90~132VAC/176~264VAC with switch
|
Input current
|
230VAC/4.3A 115VAC/8.6A
|
Efficiency
|
≥84%
|
≥84%
|
≥85%
|
≥85%
|
≥86%
|
Frequency range
|
47~63HZ
|
Leakage current
|
<3.5mA/240VAC
|
Inrush current
|
60A/230VAC cold start
|
Output
|
DC voltage
|
12V
|
15V
|
24V
|
36V
|
48V
|
Rated current
|
29.2A
|
23.3A
|
14.6A
|
9.7A
|
7.3A
|
Power
|
350.4W
|
349.5W
|
350.4W
|
349.2W
|
350.4W
|
Voltage adj.range
|
±10%
|
±10%
|
±10%
|
±10%
|
±10%
|
Ripple and noise
|
150mVp-p
|
150mVp-p
|
250mVp-p
|
250mVp-p
|
250mVp-p
|
Set up,rise time
|
≤ 3000ms ,≤ 50ms/230VAC load 100%
|
Hold up time
|
≥ 15ms/230VAC load 100%
|
Line regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load regulation
|
±1.5%
|
±1.5%
|
±1.5%
|
±1.5%
|
±1.5%
|
Output Voltage
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
EMC
|
EMS
|
compliance to: EN55035 ;EN61000-4-2,3,4,5,6,8,11
|
Harmonic current
|
NA
|
EMC
|
compliance to: EN55032 ,Class B
|
Safety
|
Safety standard
|
compliance to: GB4943.1:2022/UL62368.1:2021 -03
|
Withstand voltage
|
I/P-O/P:3KVac/5mA; I/P-CASE:I/P-CASE:1.5KVac/5mA; O/P-CASE:
O/P-CASE:0.5KVAC/5mA 1min for each test
|
Isolation resistance
|
I/P-O/P:100M ohms; I/P-Case:100M ohms; O/P-Case:50M ohms
|
Protection
|
Over voltage
|
13.5~16.5V
|
17.2~19.5V
|
27~33V
|
41~48V
|
54~64V
|
115%- 140% limited
|
Over load
|
110~150% rated Hiccup mode,auto-recovery
|
Short circuit
|
Hiccup mode,auto-recovery after remove fault condition
|
Environment
|
Working
Temp&humidity
|
-30~70C 20%~95%RH no condensing (refer to derating curve)
|
Storage
Temp&humidity
|
-40C~85C; 10%~95%RH no condensing
|
Vibration
|
10~500Hz,2G ,10min/1 cycle,60min.each along X,Y, Z axes six sweep cycles
|
Impact
|
20G ,last 11mS ,3 impacts along X, y and Z axes
|
Altitude
|
the ambient temperature derating of 0.6 C/100m for operating altitude higher than 2000m
|
Reliability
|
MTBF
|
Under 25C:250000Hrs, MIL-217 Method
|
Others
|
SIZE
|
215*115*30mm (L*W*H)
|
Packing
|
0.65Kg/pc,20pc/ctn,14KG/carton
|
Cooling mode
|
□free air convection ☑with fan
|
Extension mode
|
PCB double side conformal coating ☑ block with cover low temp start (-40C)
Other
|
Note
|
*In order to extend the service life, it is recommended to leave 30% more allowance when loading. For example, if the equipment needs 100W power, please choose the power supply over 130W.
*Ripple&noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.
*All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25C of ambient temperature.
*The power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still meets EMC directives.All our EMC tests are carried out by mounting samples on metal plates.
|